Foot Candle Requirements by Space Type

A foot candle is one lumen landing on one square foot. Everything about whether a space feels right comes back to this number, how evenly it is spread, and where somebody measured it. Here are working targets for the spaces you are most likely to be quoting.

Warehouse and industrial

Space Target Measured at
Bulk storage, infrequent access 5 to 10 fc Floor
Active storage, forklift traffic 10 to 20 fc Floor
Rack aisles, order picking 20 to 30 fc Vertical, in the aisle at rack face
General assembly 30 to 50 fc 30 inches above floor
Detailed assembly, machining 50 to 75 fc At the work
Inspection, fine detail 75 to 100 fc At the work, usually task lighting
Loading dock 20 to 30 fc Floor, plus dock lights at doors
Mechanical and electrical rooms 20 to 30 fc Floor

Fixtures: high bays above about fifteen feet, strip lights below that.

Office and commercial

Space Target Measured at
Open plan office 30 to 40 fc Desk height, 30 inches
Private office 30 to 50 fc Desk height
Conference room 30 to 40 fc Table height, dimming worth having
Corridor, lobby 10 to 20 fc Floor
Break room 20 to 30 fc Table height
Restroom 10 to 20 fc Floor, more at the mirror
Stairwell 10 fc minimum Tread, and check egress requirements
Server or IT room 30 to 50 fc Vertical at the rack face

Fixtures: panels and troffers in drop ceiling, down lights in hard ceiling, wraparounds in utility space.

Retail

Space Target Notes
General sales floor 30 to 50 fc Higher for value retail, lower for premium
Feature and display 2 to 5x the general level Contrast is what draws the eye, not raw level
Grocery, big box 50 to 75 fc Uniform and bright is the whole aesthetic
Fitting room 30 to 50 fc Colour rendering matters more than level
Checkout 50 fc Vertical light on faces, not just down
Stockroom 20 to 30 fc Floor

Schools and healthcare

Space Target Notes
Classroom 30 to 50 fc Desk height, low glare, dimming for screens
Gymnasium 30 to 50 fc Higher for competition play, uniformity critical
Library, reading 30 to 50 fc Vertical light on the stacks too
Cafeteria 20 to 30 fc Table height
Patient room 10 to 30 fc General, with separate exam lighting
Exam room 50 to 100 fc At the table, high colour rendering
Nurse station 50 fc Work surface
Corridor, daytime 10 to 20 fc Often reduced at night

Parking and exterior

Space Target Notes
Open parking lot, basic 0.5 to 1 fc average Minimum matters more than average here
Open parking lot, enhanced security 1 to 3 fc average Retail and hospitality typically
Parking garage interior 5 fc Floor, and the fixtures run 24 hours
Garage ramps and entries 10 to 20 fc daytime Eyes need a transition zone from daylight
Building entrance 5 to 10 fc Vertical light on faces for cameras
Walkway, path 0.5 to 2 fc Uniformity beats brightness
Loading and service yard 5 to 10 fc Floor
Fuel canopy 20 to 30 fc Under the canopy, and it is a dark sky issue

Fixtures: area lights on poles, wall packs on buildings, canopy under cover, bollards on paths.

The number nobody asks about: uniformity

Average foot candles will not tell you whether a space looks good. Uniformity will.

Uniformity ratio = average fc ÷ minimum fc
Space Target ratio
Office, classroom, retail 3:1 or better
Warehouse general 4:1 or better
Parking lot 4:1, and no worse than 15:1 max to min
Sports and gym 2:1, which is why these layouts get dense

A parking lot at 1.5 foot candles average sounds fine until you find out it is 6 foot candles under each pole and 0.2 between them. The average is right and the lot is unusable, because the human eye adapts to the bright spot and then cannot see into the dark one. This is the single most common reason a client says the new lighting looks worse than what came out.

Interior spaces are more forgiving than exterior. Walls and ceilings bounce light around and fill in the gaps. Outside there is nothing to bounce off, which is why pole spacing and distribution type matter so much more than fixture wattage.

How to measure so the number means something

  • Measure at the work plane, not the floor. Thirty inches for desks and benches. The floor is only the work plane in a warehouse.
  • Take a grid, not a spot. Walk a pattern and record several readings. One reading directly under a fixture proves nothing.
  • Kill the daylight. Measure at night or with blinds closed, or you are measuring the sun.
  • Let LED settle. Give fixtures a few minutes to reach steady output before reading.
  • Hold the meter flat and stand out of the way. Your own shadow will move a reading more than you expect.
  • Record the existing levels before you demo anything. It settles arguments later, and it is what the utility asks for if a rebate is involved.

Turning a target into a fixture count

Once you have a target, the lumen method gets you to a fixture count in about two minutes. That method, with a worked example, is in how many high bays do you need for a warehouse. It works the same way for panels, strips and troffers, only the fixture lumens change.

One shortcut worth knowing: most of what we carry is wattage selectable, so you can lock the layout in first and set the output afterward once you have walked the space with a meter. That is a lot easier than reordering.

Tell us the space and we will tell you the fixture

Square footage, ceiling height and what happens in the room. We will come back with the fixture, the count and a price you can put in the bid.